The monitoring network within this area

Hydrionis holds 38,331 values from 2 gauges within it. Discharge is a property of a gauge and its reach, not of this drainage area, so this page reports the network and its records rather than a single figure.

2
Gauges
38,331
Values held
1921–2026
Record spans
344 km²
Area
Gauges within the Ljungbyån drainage basin
2 monitoring points, positioned as the publisher records them.
Gauges within the Ljungbyån drainage basinKÄLLSTORP 2, KÄLLSTORPKÄLLSTORP 2KÄLLSTORP

How low, how high and how variable this gauge runs

A hydrograph says what happened; these say how often. Read off KÄLLSTORP 2's whole daily record between 1967 and 2026, they describe the shape of the record rather than any day in it — and they belong to this gauge and its reach, not to this drainage area.

0.056 m³/s
Q95 low flow
1.320 m³/s
Q50 median flow
4.790 m³/s
Q10 high flow
Largest day of each water year at KÄLLSTORP 2
The highest daily mean discharge in each October-to-September water year, 1967–2025.
Largest day of each water year at KÄLLSTORP 2Largest day of each water year at KÄLLSTORP 2: KÄLLSTORP 2 in m³/s, from 1967 to 2025.01020m³/s19671975198319911999200720152023KÄLLSTORP 2 1967: 21.6 m³/sKÄLLSTORP 2 1968: 12.4 m³/sKÄLLSTORP 2 1969: 21.7 m³/sKÄLLSTORP 2 1970: 11.1 m³/sKÄLLSTORP 2 1971: 18.3 m³/sKÄLLSTORP 2 1972: 10.5 m³/sKÄLLSTORP 2 1973: 4.78 m³/sKÄLLSTORP 2 1974: 7.05 m³/sKÄLLSTORP 2 1975: 4.93 m³/sKÄLLSTORP 2 1976: 21.8 m³/sKÄLLSTORP 2 1977: 11.7 m³/sKÄLLSTORP 2 1978: 13.7 m³/sKÄLLSTORP 2 1979: 9.31 m³/sKÄLLSTORP 2 1980: 11.4 m³/sKÄLLSTORP 2 1981: 9.73 m³/sKÄLLSTORP 2 1982: 5.94 m³/sKÄLLSTORP 2 1983: 5.63 m³/sKÄLLSTORP 2 1984: 19.1 m³/sKÄLLSTORP 2 1985: 12.4 m³/sKÄLLSTORP 2 1986: 10.9 m³/sKÄLLSTORP 2 1987: 13.7 m³/sKÄLLSTORP 2 1988: 5.14 m³/sKÄLLSTORP 2 1989: 7.00 m³/sKÄLLSTORP 2 1990: 5.68 m³/sKÄLLSTORP 2 1991: 4.50 m³/sKÄLLSTORP 2 1992: 5.57 m³/sKÄLLSTORP 2 1993: 13.1 m³/sKÄLLSTORP 2 1994: 10.9 m³/sKÄLLSTORP 2 1995: 15.9 m³/sKÄLLSTORP 2 1996: 7.57 m³/sKÄLLSTORP 2 1997: 5.18 m³/sKÄLLSTORP 2 1998: 10.3 m³/sKÄLLSTORP 2 1999: 6.45 m³/sKÄLLSTORP 2 2000: 9.11 m³/sKÄLLSTORP 2 2001: 12.3 m³/sKÄLLSTORP 2 2002: 6.69 m³/sKÄLLSTORP 2 2003: 10.6 m³/sKÄLLSTORP 2 2004: 10.0 m³/sKÄLLSTORP 2 2005: 18.2 m³/sKÄLLSTORP 2 2006: 12.0 m³/sKÄLLSTORP 2 2007: 5.63 m³/sKÄLLSTORP 2 2008: 5.64 m³/sKÄLLSTORP 2 2009: 12.1 m³/sKÄLLSTORP 2 2010: 21.5 m³/sKÄLLSTORP 2 2011: 7.43 m³/sKÄLLSTORP 2 2012: 10.5 m³/sKÄLLSTORP 2 2013: 5.30 m³/sKÄLLSTORP 2 2014: 7.01 m³/sKÄLLSTORP 2 2015: 3.83 m³/sKÄLLSTORP 2 2016: 12.8 m³/sKÄLLSTORP 2 2017: 10.2 m³/sKÄLLSTORP 2 2018: 7.70 m³/sKÄLLSTORP 2 2019: 11.1 m³/sKÄLLSTORP 2 2020: 5.68 m³/sKÄLLSTORP 2 2021: 10.0 m³/sKÄLLSTORP 2 2022: 11.4 m³/sKÄLLSTORP 2 2023: 9.18 m³/sKÄLLSTORP 2 2024: 4.87 m³/sKÄLLSTORP 2 2025: 6.03 m³/s

These are the largest daily means, not flood peaks. A peak lasting hours is averaged across a whole day here, so the true instantaneous maximum on the same day was higher — sometimes far higher on a fast-responding catchment. Flood frequency work needs a publisher's own instantaneous series; Hydrionis holds one for 2,236 American gauges and not for this one, so the two are never drawn together. A water year the gauge did not substantially cover produces no value at all rather than a low one.

View the data behind this chart
Underlying data
PeriodKÄLLSTORP 2 (m³/s)
196721.6
196812.4
196921.7
197011.1
197118.3
197210.5
19734.78
19747.05
19754.93
197621.8
197711.7
197813.7
19799.31
198011.4
19819.73
19825.94
19835.63
198419.1
198512.4
198610.9
198713.7
19885.14
19897.00
19905.68
19914.50
19925.57
199313.1
199410.9
199515.9
19967.57
19975.18
199810.3
19996.45
20009.11
200112.3
20026.69
200310.6
200410.0
200518.2
200612.0
20075.63
20085.64
200912.1
201021.5
20117.43
201210.5
20135.30
20147.01
20153.83
201612.8
201710.2
20187.70
201911.1
20205.68
202110.0
202211.4
20239.18
20244.87
20256.03

The longest record here

Mean river flow at KÄLLSTORP 2
Annual means of the daily record, 1968–2025. One gauge, not this drainage area.
Mean river flow at KÄLLSTORP 2Mean river flow at KÄLLSTORP 2: KÄLLSTORP 2 in m³/s, from 1968 to 2025.123m³/s19681976198419922000200820162024KÄLLSTORP 2 1968: 2.39 m³/sKÄLLSTORP 2 1969: 2.10 m³/sKÄLLSTORP 2 1970: 3.08 m³/sKÄLLSTORP 2 1971: 1.19 m³/sKÄLLSTORP 2 1972: 1.46 m³/sKÄLLSTORP 2 1973: 1.89 m³/sKÄLLSTORP 2 1974: 1.93 m³/sKÄLLSTORP 2 1975: 1.42 m³/sKÄLLSTORP 2 1976: 1.41 m³/sKÄLLSTORP 2 1977: 2.60 m³/sKÄLLSTORP 2 1978: 2.20 m³/sKÄLLSTORP 2 1979: 2.34 m³/sKÄLLSTORP 2 1980: 2.13 m³/sKÄLLSTORP 2 1981: 2.30 m³/sKÄLLSTORP 2 1982: 1.63 m³/sKÄLLSTORP 2 1983: 1.51 m³/sKÄLLSTORP 2 1984: 2.96 m³/sKÄLLSTORP 2 1985: 2.62 m³/sKÄLLSTORP 2 1986: 2.00 m³/sKÄLLSTORP 2 1987: 2.45 m³/sKÄLLSTORP 2 1988: 3.12 m³/sKÄLLSTORP 2 1989: 1.22 m³/sKÄLLSTORP 2 1990: 1.56 m³/sKÄLLSTORP 2 1991: 1.29 m³/sKÄLLSTORP 2 1992: 1.56 m³/sKÄLLSTORP 2 1993: 2.02 m³/sKÄLLSTORP 2 1994: 3.11 m³/sKÄLLSTORP 2 1995: 2.48 m³/sKÄLLSTORP 2 1996: 2.35 m³/sKÄLLSTORP 2 1997: 1.57 m³/sKÄLLSTORP 2 1998: 2.01 m³/sKÄLLSTORP 2 1999: 1.97 m³/sKÄLLSTORP 2 2000: 2.16 m³/sKÄLLSTORP 2 2001: 2.25 m³/sKÄLLSTORP 2 2002: 2.07 m³/sKÄLLSTORP 2 2003: 1.51 m³/sKÄLLSTORP 2 2004: 2.64 m³/sKÄLLSTORP 2 2005: 1.48 m³/sKÄLLSTORP 2 2006: 2.47 m³/sKÄLLSTORP 2 2007: 2.82 m³/sKÄLLSTORP 2 2008: 2.03 m³/sKÄLLSTORP 2 2009: 1.07 m³/sKÄLLSTORP 2 2010: 2.52 m³/sKÄLLSTORP 2 2011: 2.35 m³/sKÄLLSTORP 2 2012: 1.78 m³/sKÄLLSTORP 2 2013: 1.84 m³/sKÄLLSTORP 2 2014: 2.23 m³/sKÄLLSTORP 2 2015: 1.70 m³/sKÄLLSTORP 2 2016: 1.84 m³/sKÄLLSTORP 2 2017: 1.68 m³/sKÄLLSTORP 2 2018: 2.03 m³/sKÄLLSTORP 2 2019: 1.81 m³/sKÄLLSTORP 2 2020: 1.68 m³/sKÄLLSTORP 2 2021: 2.51 m³/sKÄLLSTORP 2 2022: 1.41 m³/sKÄLLSTORP 2 2023: 2.16 m³/sKÄLLSTORP 2 2024: 1.91 m³/sKÄLLSTORP 2 2025: 1.11 m³/s

Annual means computed by Hydrionis from the published daily record, drawn only for years with at least 300 days held. They summarise this gauge's own record and say nothing about any other watercourse in this area.

View the data behind this chart
Underlying data
PeriodKÄLLSTORP 2 (m³/s)
19682.39
19692.10
19703.08
19711.19
19721.46
19731.89
19741.93
19751.42
19761.41
19772.60
19782.20
19792.34
19802.13
19812.30
19821.63
19831.51
19842.96
19852.62
19862.00
19872.45
19883.12
19891.22
19901.56
19911.29
19921.56
19932.02
19943.11
19952.48
19962.35
19971.57
19982.01
19991.97
20002.16
20012.25
20022.07
20031.51
20042.64
20051.48
20062.47
20072.82
20082.03
20091.07
20102.52
20112.35
20121.78
20131.84
20142.23
20151.70
20161.84
20171.68
20182.03
20191.81
20201.68
20212.51
20221.41
20232.16
20241.91
20251.11

Every gauge Hydrionis holds within this area

Gauges within the Ljungbyån and what each holds
GaugeMeasuresValuesRecord
KÄLLSTORP 2mean river flow21,5611967–2026
KÄLLSTORPmean river flow16,7701921–1967

How these gauges were attached to this water

Assigned by the publisher to a numbered basin Every gauge here is assigned to this drainage area by its own publisher, which issues the area an official code — 77000. A drainage area is not a river: it contains the tributaries as well as the main channel, and a gauge in it may be on any of them.

What each gauge’s link to this water rests on
GaugeEvidenceEstablished
KÄLLSTORP 2Stated by the publisher on the record this gauge’s observations came from.With the observations
KÄLLSTORPStated by the publisher on the record this gauge’s observations came from.With the observations

What this record holds

Hydrionis decides which waters get a page, and which of those are offered to search, from what is actually held rather than from how the page reads. Five signals are counted; this record has 2 of them, which makes it a profile, not indexed.

Information-gain signals held for this water body
SignalHeldCounts
Gauges holding a real record2no
Years spanned106yes, 20 or more
Values held38,331yes, 1000 or more
Distinct measurements1no
Publishers measuring it1no
Official identifiers2recorded, not counted

Use this data

Use this data

No bulk download is offered here, which is a licence position rather than a product one: at least one contributing publisher does not permit redistribution. The values can be read on the page, cited, and pointed to at source.

Attribution and citation

Attribution you are required to give

These are conditions of the licences the underlying data is published under. They are obligations to the publishers, not to Hydrionis, and they apply to you directly whether or not you mention Hydrionis at all.

Data from Sveriges meteorologiska och hydrologiska institut, used under CC BY 4.0.

Suggested citation for Hydrionis

Hydrionis (2026), Ljungbyån gauge records, accessed 2026-10-05, hydrionis.com/waters/sweden-ljungbyan/

Cite Hydrionis where you rely on the compilation, the normalisation, the eligibility judgements or a chart. Where you use an unmodified published value, the publisher’s attribution is the one that is required; crediting Hydrionis as well is welcome and is not something Hydrionis can require of you.

Recommended, not required. Hydrionis does not claim rights over unmodified public data it relayed, and doing arithmetic on somebody else’s measurements does not make them Hydrionis’s. Cite the version and the access date: the Ljungbyån gauge records changes as publishers release and as methods are revised, and a citation without both cannot be checked later. Full guidance is on cite and reuse.

Where these figures come from

MeasuredMedium confidence2026-09-30

Source: SMHI — Swedish hydrological observations, 1962. Licence: Open — attribution required (attribution required).

Method: Daily discharge exactly as SMHI publishes it, from its corrected archive. SMHI computes the daily value from its own sub-daily measurement and rating curves; Hydrionis does not recompute it, because a mean derived from whatever sub-daily data happens to be exposed would be a different statistic under the same name.

Checked and approved by SMHI except 2026-01-14 to 2026-09-30 (not yet checked). Station in the LJUNGBYÅN main drainage basin, 342 km². Discharge is a property of this gauge and this reach, not of the river as a whole.

Retrieved 1 October 2026.