Key facts

Unit
NTU
Metric
Turbidity

What it measures

Light scattered by suspended particles at 90 degrees to an incident beam. It counts nothing directly; it responds to particle number, size and shape.

How it is measured

By nephelometer, reported in nephelometric turbidity units. Continuous online monitoring on each filter is standard practice at modern works.

How to read a value

Interpretation bands for turbidity
Value (NTU)What it indicates
Below 0.1Excellent filtered water. The operational target for works treating Cryptosporidium-risk sources.
0.1 – 0.5Good treated water.
0.5 – 1Acceptable but indicates reduced filter performance.
Above 4Visible cloudiness; the regulatory limit at the consumer tap in several jurisdictions.

Bands are conventional interpretation aids, not regulatory limits. Where a legal standard exists it is stated on the relevant standards page.

What causes it

  • Clay and silt washed in after rainfall
  • Algae in reservoirs
  • Iron and manganese precipitates
  • Disturbed sediment in distribution mains

Why it matters

  • Filter performance is judged by turbidity because it responds within seconds, whereas a microbiological result takes at least a day
  • A turbidity spike after rainfall is the classic signature of a Cryptosporidium risk event
  • Discoloured water at the tap with normal turbidity at the works points to the distribution network rather than to treatment